LUNCH & LEARN
DECLARE™ LABEL
SUSTAINABILITY
QUALITY ASSURANCE
FIND A REP

Advantages

INTERIOR PARTITIONS (non-load bearing)

R-stud meets CCRR, E119 & STC testing. The acoustical testing alone shows R-stud’s performance 3-5/8” stud @ 24”o.c. using R-13 unfaced insulation with one layer of 5/8” gypsum type X provides a 50 STC (Sound Transmission Class) rating, beating generic steel studs by nine points...saves money by using less materials like gypsum board and less labor installing that extra layer. The design in R-stud significantly increases product performance, including greater load capacity, higher limiting heights, better acoustical, better R-values and easier installation.

Common Stud Sizes Offered

3-5/8"

4"

6"

Part #

Galv

Grade

Part #

Galv

Grade

Part #

Galv

Grade

362RS125-19

G60

50

400RS125-19

G60

50

600RS162-19

G60

50

362RS162-19

G60

50

400RS137-19

G60

50

600RS162-23

G60

50

362RS162-23

G60

50

400RS162-19

G60

50

600RS162-30

G60

50

362RS125-30

G60

50

400RS162-23

G60

50

600RS162-34

G90

50

362RS162-30

G60

50

400RS137-30

G60

50

600RS162-43

G90

50

362RS162-34

G90

50

400RS162-30

G60

50

600RS162-54

G90

55

362RS162-43

G90

50

400RS137-34

G90

50

600RS175-57

G90

55

400RS163-34

G90

50

600RS200-54

G90

55

400RS162-43

G90

50

600RS162-60

G90

55

400RS200-43

G90

50

600RS200-60

G90

55

Drywall

 

 

Structural

Additional "Custom" sized studs can be made. Flange widths may be ordered in 1-3/8", 1-1/2", 1-3/4" and 2".

Sound Assemblies

STC 52

STC 55

Product Data

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
18 mil stud (3.625")

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
30 mil stud (3.625")

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
43 mil stud (3.625")

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
54 mil stud (3.625")

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
18 mil stud (6")

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
30 mil stud (6")

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
43 mil stud (6")

EXTERIOR STUDS (load-bearing)

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
18 mil stud

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
30 mil stud

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
43 mil stud

 
DOCUMENTATION

 3-Part Specifications (MS WORD)

 Limiting Wall Heights

 Thermal Performance

 Transverse Load Test

 STC Assemblies 

 Code Compliance Report



DOWNLOAD STC CHART
54 mil stud